Location Category |
Internal mounting location only. Must be installed within a suitable enclosed space, allowing for cooling airflow |
Dimensions - Including hinges (H x W x D, mm) |
520 x 240 x 220 |
Weight (kg) |
6 |
Warranty |
5 years, workmanship and materials |
Installation instructions |
Supplied with unit |
Input voltage (Uc) |
220 – 250VAC |
Max Continuous Voltage (Mcov) |
320VAC L-N |
Service type |
TN-S, TN C-S SYSTEMS |
Nominal discharge current |
Class II In L-N 50kA, N-E 50 kA |
Current rating – continuous |
50, 63 or 80A |
Recommended maximum over current protection |
HRC gL fuse rated according to the unit’s rating |
Residual current |
<10 mA |
Short circuit withstand (1 sec) |
29kA |
Primary protection modes |
Line-Neutral, Neutral-Earth |
In 8/20us (Line-Neutral or Line-Earth) |
50kA |
In 8/20us (Neutral-Earth) |
50kA |
Ismax 8/20us ( Line – Neutral ) |
100kA |
Nominal surge lifetime |
15 hits @ 50kA (8/20uS, each mode) |
Filter attenuation |
48dB nominal above 1MHz |
Initial clamp voltage (Line-Neutral) |
510V |
Initial clamp voltage (Neutral-Earth) |
255V |
Residual voltage (Vpl) Line-Neutral |
<600V (3kA, 8/20uS) |
Residual voltage (Vpl) Neutral-Earth |
<1000V (3kA, 8/20uS) |
Residual voltage (Vpl) Line-Neutral |
<800V (50kA, 8/20uS) |
Residual voltage (Vpl) Neutral-Earth |
<1100V (50kA, 8/20uS) |
Internal protection (fusing) |
All surge diverter elements are thermally fused |
External disconnector requirements |
Line side: 1 or 3 pole, HRC gL fuse, 500v, 50KAIC
Load side: 10kAIC or better MCB |
Terminations |
Bolted lug. 8mm bolts for phase and neutral connections. 6mm PE (earth) stud provided on gear tray. All connections identified on unit. |
Thermal dissipation |
Max 200W @ full load, 3 phase, 80A model |
Alarms/indicators |
Includes status indicators, dry contact alarm relay output (normally-closed with power applied and all SPD’s at 100% capacity). Contact rating 250Vac/32Vdc, 5A, alarm under-voltage cut off 180Vac. |
Enclosure rating |
IP42 |
Standards. Designed in accordance with : |
IEC61643-1:2005, IEC610006-1,2,3,4 ANSI/IEEE C62.41, AS/NZS1768, AS/NZS3000:2007, AS3100 |
Environment |
-10 to 65°C, 10 to 90%RH (non-condensing) |